Technical parameters:
Environmental conditions
The coupler should be able to operate normally under the following conditions:
a) Environmental temperature: 0 ℃ to+40 ℃;
b) Average relative humidity: ≤ 90% (+25 ℃);
c) Atmospheric pressure: 86kPa~106kPa;
d) Places without significant vibration and impact;
e) A safe place without methane, coal dust, etc. on the ground.
The worst storage and transportation conditions that the coupler should be able to withstand are:
a) High temperature:+60 ℃;
b) Low temperature: -40 ℃;
c) Average relative humidity: 95% RH;
d) Vibration: Acceleration of 20m/s2;
e) The peak acceleration of the impact is 300m/s2.
User line conditions
The maximum distance between the coupler and the underground telephone is 10km (the model and specification of the mining cable are: MHYAV, MHYBV, MHYA32. The wire diameter is 0.8mm) The user line parameters are:
a) Direct current resistance of conductive wire core: ≤ 36.7 Ω/km;
b) Capacitor: ≤ 0.06 μ F/km;
c) Inductance: ≤ 800mH/km;
d) Minimum insulation resistance: 15k Ω~20k Ω.
Input and output parameters of coupler
1. Non intrinsic safety input parameters
a) Maximum DC input voltage: ≤ 60V;
b) Maximum DC input current: ≤ 60mA;
c) Maximum input voltage of ringing current: ≤ 90V;
d) Maximum input current for bell current: ≤ 90mA.
2. Intrinsic safety end output parameters
a) DC maximum open circuit voltage: ≤ 60V;
b) Maximum DC short-circuit current: ≤ 34mA;
c) Maximum open circuit voltage of ringing current: ≤ 60V;
d) Maximum short-circuit current of bell current: ≤ 38mA.